{"title":"ABB RCBOs","description":"\u003ch1\u003e ABB MCB\/RCBO (RCBO) – Compact protection for individual circuits\u003c\/h1\u003e\n\n\n\u003cp\u003e\n With an \u003cstrong\u003eABB LS-FI switch\u003c\/strong\u003e (also known as \u003cstrong\u003eFI\/LS\u003c\/strong\u003e or \u003cstrong\u003eRCBO\u003c\/strong\u003e ) you get\n \u003cstrong\u003eResidual current protection\u003c\/strong\u003e and \u003cstrong\u003eline protection\u003c\/strong\u003e in one device.\n This means: protection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e (residual current) plus protection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \n\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e – ideal if you want to protect individual circuits separately.\n\u003c\/p\u003e\n\n\n\u003cp\u003e\n This product overview contains a wide selection of \u003cstrong\u003eABB RCBOs (residual current circuit breakers\/miniature circuit breakers).\u003c\/strong\u003e\n For residential, commercial and industrial buildings – in various pole counts, rated currents, and tripping characteristics.\n and residual current types.\n\u003c\/p\u003e\n\n\n\u003ch2\u003e Why ABB LS-FI switches?\u003c\/h2\u003e\n\n\n\u003cp\u003e\n ABB stands for reliable protection technology and clean workmanship. ABB's residual current circuit breakers (RCCBs) are particularly practical,\n if you want more safety per circuit without overloading the distribution board with multiple devices.\n\u003c\/p\u003e\n\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003e2-in-1 protection:\u003c\/strong\u003e RCD + MCB in one device\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eSpace-saving:\u003c\/strong\u003e ideal for compact sub-distribution boards\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFaster fault finding:\u003c\/strong\u003e the affected circuit is clearly identifiable\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eLess wiring:\u003c\/strong\u003e saves time during assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRobust \u0026amp; durable:\u003c\/strong\u003e for continuous use\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch2\u003e ABB Series Overview: DS201 \u0026amp; DS202C\u003c\/h2\u003e\n\n\n\u003cp\u003e \nCommon ABB FI\/LS series include \u003cstrong\u003eDS201\u003c\/strong\u003e (mostly 1P+N) and \u003cstrong\u003eDS202C.\u003c\/strong\u003e\n (Compact versions depending on the application). They are ideal if you want to target individual consumers,\n If you want to protect rooms or critical areas separately.\n\u003c\/p\u003e\n\n\n\u003ch3\u003e Typical characteristics:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Configurations such as \u003cstrong\u003e1P+N\u003c\/strong\u003e (typical for single final circuits)\u003c\/li\u003e\n\n\u003cli\u003e Rated current e.g. \u003cstrong\u003e6A, 10A, 13A, 16A, 20A, 25A, 32A\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e Characteristics often \u003cstrong\u003eB\u003c\/strong\u003e or \u003cstrong\u003eC\u003c\/strong\u003e (depending on the load)\u003c\/li\u003e\n\n\u003cli\u003e Residual current tripping current e.g. \u003cstrong\u003e30 mA\u003c\/strong\u003e (personal protection)\u003c\/li\u003e\n\n\u003cli\u003e Residual current type as required, e.g. \u003cstrong\u003etype A\u003c\/strong\u003e (widely used)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch2\u003e When is a residual current circuit breaker (RCCB) particularly useful?\u003c\/h2\u003e\n\n\n\u003cp\u003e\n An \u003cstrong\u003eABB RCBO\u003c\/strong\u003e is often the best choice if you want to protect individual circuits separately or\n if outages are only supposed to affect a small area.\n\u003c\/p\u003e\n\n\n\u003cul\u003e\n\n\u003cli\u003e kitchen, bathroom or outdoor areas\u003c\/li\u003e\n\n     \u003cli\u003eWashing machine, dryer, dishwasher\u003c\/li\u003e\n\n\u003cli\u003e Servers, network, sensitive technology\u003c\/li\u003e\n\n\u003cli\u003e Workshop and garage electrical circuits\u003c\/li\u003e\n\n\u003cli\u003e Commercial individual consumers\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch2\u003e How to choose the right ABB RCBO\u003c\/h2\u003e\n\n\n\u003cp\u003e\n To ensure the protection is truly suitable for your installation, pay particular attention to:\n\u003c\/p\u003e\n\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e e.g. 1P+N\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current (A):\u003c\/strong\u003e suitable for the cable and fuse\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic:\u003c\/strong\u003e B for standard circuits, C for higher inrush currents\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTripping current (mA):\u003c\/strong\u003e often 30 mA for personal protection\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eResidual current type:\u003c\/strong\u003e suitable for the load (e.g., type A)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch2\u003e Buy ABB LS-FI switches online\u003c\/h2\u003e\n\n\n\u003cp\u003e\n Discover our range of \u003cstrong\u003eABB MCBs and RCBOs\u003c\/strong\u003e now and find the right RCBO combination.\n for your application. With fast delivery, fair prices and technical advice, you get exactly the protection you need.\n The one you need – compact, reliable and compliant with standards.\n\u003c\/p\u003e","products":[{"product_id":"abb-fi-ls-schalter-ds201-1-n-30ma-13a-b-typ-a-ds201-b13-a30","title":"ABB Residual Current Circuit Breaker DS201, 1+N, 30mA, 13A, B, Type A - DS201 B13 A30","description":"\u003ch2\u003e ABB DS201 B13 A30 – RCBO for combined residual current and line protection\u003c\/h2\u003e\n\n\n\u003cp\u003e The ABB DS201 B13 A30 provides combined residual current and line protection for AC circuits. It trips at a fault current of 30 mA and in case of overload from 13 A. Furthermore, as a Type A device, it detects both AC and pulsating DC fault currents.\u003c\/p\u003e\n\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic B:\u003c\/strong\u003e Perfect for lighting, sockets and household appliances (13 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a Type A circuit breaker, the DS201 B13 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its Type B tripping characteristic triggers at 3 to 5 times the rated current. Therefore, this circuit breaker is particularly suitable for lighting, sockets, and typical household appliances.\u003c\/p\u003e\n\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR255180R1135\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 13 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e B\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS201 B13 A30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630177005946,"sku":"VER0311 \/ 2CSR255180R1135","price":64.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255180R1135_Bild1.webp?v=1772210211"},{"product_id":"abb-fi-ls-schalter-ds201-m-1-n-30ma-13a-b-typ-a-g-ds201-m-b13-g30","title":"ABB FI-LS switch DS201 M, 1+N, 30mA, 13A, B, type A\/G - DS201 M B13 G30","description":"\u003ch2\u003eABB DS201 M B13 G30 – Residual Current Circuit Breaker with Short-Time Delay (Type G)\u003c\/h2\u003e\n\n\n\u003cp\u003e The ABB DS201 M B13 G30 from the DS201 M series offers combined residual current and line protection with increased breaking capacity. It protects at a rated current of 13 A and trips at a fault current of 30 mA. This provides personal, property, and line protection in a single device.\u003c\/p\u003e\n\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic B:\u003c\/strong\u003e Perfect for lighting, sockets and household appliances (13 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eShort-time delayed (Type G):\u003c\/strong\u003e Prevents false tripping due to short surge currents – proven according to ÖVE standard.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n \u003cp\u003eAs a type A\/G circuit breaker with short-time delay, the DS201 M B13 G30 detects alternating fault currents and pulsating direct fault currents. The delay prevents unwanted tripping during short surge currents. Therefore, it is widely used in Austria, particularly according to the ÖVE standard. Its tripping characteristic B triggers at 3 to 5 times the rated current. This makes the circuit breaker especially suitable for lighting, sockets, and typical household appliances.\u003c\/p\u003e\n\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR275482R1135\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 13 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e B\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\/G\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS201 M B13 G30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630177563002,"sku":"VER0312 \/ 2CSR275482R1135","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR275482R1135_Bild2.webp?v=1772211655"},{"product_id":"abb-fi-ls-schalter-ds201-1-n-30ma-13a-b-typ-a-g-ds201-b13-g30","title":"ABB FI-LS switch DS201, 1+N, 30mA, 13A, B, type A\/G - DS201 B13 G30","description":"\u003ch2\u003e ABB DS201 B13 G30 – Residual Current Circuit Breaker with Short-Time Delay (Type G)\u003c\/h2\u003e\n\n\n\u003cp\u003e The ABB DS201 B13 G30 combines residual current and line protection in a single compact device. It provides protection at a rated current of 13 A and trips at a residual current of 30 mA. This gives you personal, property, and line protection in just 2 modular units.\u003c\/p\u003e\n\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic B:\u003c\/strong\u003e Perfect for lighting, sockets and household appliances (13 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eShort-time delayed (Type G):\u003c\/strong\u003e Prevents false tripping due to short surge currents – proven according to ÖVE standard.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a type A\/G circuit breaker with short-time delay, the DS201 B13 G30 detects alternating fault currents and pulsating direct fault currents. The delay prevents unwanted tripping during short surge currents. Therefore, it is widely used in Austria, particularly according to the ÖVE standard. The tripping characteristic B triggers at just 3 to 5 times the rated current. This makes the circuit breaker especially suitable for lighting, sockets, and typical household appliances.\u003c\/p\u003e\n\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eItem number:\u003c\/strong\u003e 2CSR255482R1135\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 13 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e B\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\/G\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS201 B13 G30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n \u003cli\u003eDIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630177595770,"sku":"VER0313 \/ 2CSR255482R1135","price":69.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255482R1135_Bild2.webp?v=1772211607"},{"product_id":"abb-fi-ls-schalter-ds201-m-1-n-30ma-13a-b-typ-a-ds201-m-b13-a30","title":"ABB FI-LS switch DS201 M, 1+N, 30mA, 13A, B, type A - DS201 M B13 A30","description":"\u003ch2\u003e ABB DS201 M B13 A30 – Residual Current Circuit Breaker with Increased Breaking Capacity\u003c\/h2\u003e\n\n\n\u003cp\u003e Dual protection with the proven DS201 M series: The ABB DS201 M B13 A30 combines residual current and overcurrent protection in just 2 modules. Furthermore, its increased breaking capacity offers additional safety reserves. Consequently, it is also suitable for demanding installation conditions.\u003c\/p\u003e\n\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic B:\u003c\/strong\u003e Perfect for lighting, sockets and household appliances (13 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n \u003ch3\u003eProtective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a Type A circuit breaker, the DS201 M B13 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its Type B tripping characteristic triggers at 3 to 5 times the rated current. Therefore, this circuit breaker is particularly suitable for lighting, sockets, and typical household appliances.\u003c\/p\u003e\n\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR275180R1135\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 13 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e B\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n \u003ch3\u003eAssembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS201 M B13 A30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630177628538,"sku":"VER0314 \/ 2CSR275180R1135","price":89.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR275180R1135_Bild1.webp?v=1772211537"},{"product_id":"abb-fi-ls-schalter-ds201-1-n-30ma-16a-b-typ-a-ds201-b16-a30","title":"ABB Residual Current Circuit Breaker DS201, 1+N, 30mA, 16A, B, Type A - DS201 B16 A30","description":"\u003ch2\u003e ABB DS201 B16 A30 – RCBO for combined residual current and line protection\u003c\/h2\u003e\n\n\n\u003cp\u003e The ABB DS201 B16 A30 combines residual current and line protection in a single compact device. It provides protection at a rated current of 16 A and trips at a residual current of 30 mA. This gives you personal, property, and line protection in just 2 modular units.\u003c\/p\u003e\n\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic B:\u003c\/strong\u003e Perfect for lighting, sockets and household appliances (16 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a Type A circuit breaker, the DS201 B16 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its Type B tripping characteristic triggers at 3 to 5 times the rated current. Therefore, this circuit breaker is particularly suitable for lighting, sockets, and typical household appliances.\u003c\/p\u003e\n\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR255180R1165\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e B\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS201 B16 A30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630177956218,"sku":"VER0315 \/ 2CSR255180R1165","price":62.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255180R1165_Bild1.webp?v=1772211489"},{"product_id":"abb-fi-ls-schalter-ds201-1-n-30ma-16a-b-typ-a-g-ds201-b16-g30","title":"ABB FI-LS switch DS201, 1+N, 30mA, 16A, B, type A\/G - DS201 B16 G30","description":"\u003ch2\u003eABB DS201 B16 G30 – Residual Current Circuit Breaker with Short-Time Delay (Type G)\u003c\/h2\u003e\n\n\n\u003cp\u003e The ABB DS201 B16 G30 combines residual current and line protection in a single compact device. It provides protection at a rated current of 16 A and trips at a residual current of 30 mA. This gives you personal, property, and line protection in just two modular units.\u003c\/p\u003e\n\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic B:\u003c\/strong\u003e Perfect for lighting, sockets and household appliances (16 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eShort-time delayed (Type G):\u003c\/strong\u003e Prevents false tripping due to short surge currents – proven according to ÖVE standard.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n \u003cp\u003eAs a type A\/G circuit breaker with short-time delay, the DS201 B16 G30 detects alternating fault currents and pulsating direct fault currents. The delay prevents unwanted tripping during short surge currents. Therefore, it is widely used in Austria, particularly according to the ÖVE standard. Its tripping characteristic B triggers at 3 to 5 times the rated current. This makes the circuit breaker especially suitable for lighting, sockets, and typical household appliances.\u003c\/p\u003e\n\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eItem number:\u003c\/strong\u003e 2CSR255482R1165\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e B\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\/G\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS201 B16 G30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630178120058,"sku":"VER0316 \/ 2CSR255482R1165","price":62.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255482R1165_Bild2.webp?v=1772211456"},{"product_id":"abb-fi-ls-schalter-flexline-1-n-30ma-16a-b-typ-a-dsx301c-b16-a30","title":"ABB Residual Current Circuit Breaker FlexLine, 1+N, 30mA, 16A, B, Type A - DSX301C B16 A30","description":"\u003ch2\u003eABB DSX301C B16 A30 – Residual Current Circuit Breaker with Push-in Technology (FlexLine)\u003c\/h2\u003e\n\n\u003cp\u003e The ABB DSX301C B16 A30 combines residual current and circuit protection in a compact device with push-in technology. This RCBO offers a rated current of 16 A and a residual current tripping current of 30 mA. Thanks to the push-in terminals on the output terminals, wiring is particularly quick. Furthermore, the compact 1-TE design saves valuable space in the distribution board.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic B:\u003c\/strong\u003e Perfect for lighting, sockets and household appliances (16 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePush-in technology:\u003c\/strong\u003e Tool-free wiring at the outlet for quick assembly.\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eCompact:\u003c\/strong\u003e Only 1 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a Type A circuit breaker, the DSX301C B16 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its Type B tripping characteristic triggers at 3 to 5 times the rated current. Therefore, this circuit breaker is particularly suitable for lighting, sockets, and typical household appliances.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR255165R1165\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e B\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eTerminal type:\u003c\/strong\u003e Push-in terminals (output) \/ Screw terminals (input)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 10 mm² (push-in), up to 25 mm² (screw)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 1 TE\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DSX301C B16 A30 snaps directly onto the 35 mm DIN rail. On the input side, you can use the screw terminal or the PSX busbar. On the output side, you connect the conductors without tools using the push-in terminals. This makes wiring particularly quick and secure. Furthermore, feed-in from both the top and bottom is possible. In addition, the integrated test button simplifies regular functional testing of the residual current device (RCD). The IP20 protection rating of the terminals also ensures reliable protection against accidental contact.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630178283898,"sku":"VER0317 \/ 2CSR255165R1165","price":64.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255165R1165_Bild1.webp?v=1772211383"},{"product_id":"abb-fi-ls-schalter-ds201-1-n-30ma-10a-c-typ-a-ds201-c10-a30","title":"ABB Residual Current Circuit Breaker DS201, 1+N, 30mA, 10A, C, Type A - DS201 C10 A30","description":"\u003ch2\u003e ABB DS201 C10 A30 – RCBO for combined residual current and line protection\u003c\/h2\u003e\n\n \u003cp\u003eThe ABB DS201 C10 A30 provides combined residual current and line protection for AC circuits. It trips at a fault current of 30 mA and in case of overload from 10 A. Furthermore, as a Type A device, it detects both AC and pulsating DC fault currents.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (10 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n \u003cp\u003eAs a Type A residual current device (RCD), the DS201 C10 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its C-type tripping characteristic triggers at 5 to 10 times the rated current. Therefore, it is also suitable for devices with higher inrush currents.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR255180R1104\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 10 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n \u003cp\u003eThe DS201 C10 A30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630178546042,"sku":"VER0318 \/ 2CSR255180R1104","price":72.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255180R1104_Bild1.webp?v=1772211328"},{"product_id":"abb-fi-ls-schalter-ds201-1-n-30ma-10a-c-typ-a-apr-ds201-c10-apr30","title":"ABB Residual Current Circuit Breaker DS201, 1+N, 30mA, 10A, C, Type A APR - DS201 C10 APR30","description":"\u003ch2\u003e ABB DS201 C10 APR30 – Residual Current Circuit Breaker with Overvoltage Release\u003c\/h2\u003e\n\n\u003cp\u003e The ABB DS201 C10 APR30 offers combined residual current and line protection with an integrated surge protector (APR). It protects against fault currents of up to 10 A and a residual current of up to 30 mA. Additionally, the APR mechanism detects dangerous overvoltages and disconnects the circuit. This provides triple protection in a single device.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (10 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eAutomatic Voltage Release (APR):\u003c\/strong\u003e Detects dangerous overvoltages and switches off automatically.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n \u003cp\u003eThe DS201 C10 APR30 offers integrated surge protection in addition to residual current protection (Type A). This allows it to detect both fault currents and dangerous overvoltages, providing triple protection against overload, fault currents, and overvoltage. The C-type tripping characteristic triggers at 5 to 10 times the rated current, making it suitable for devices with higher inrush currents.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR255480R1104\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 10 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A APR\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n \u003cp\u003eThe DS201 C10 APR30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630178873722,"sku":"VER0319 \/ 2CSR255480R1104","price":99.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255480R1104_Bild2.webp?v=1772211295"},{"product_id":"abb-fi-ls-schalter-ds201-1-n-30ma-13a-c-typ-a-ds201-c13-a30","title":"ABB Residual Current Circuit Breaker DS201, 1+N, 30mA, 13A, C, Type A - DS201 C13 A30","description":"\u003ch2\u003e ABB DS201 C13 A30 – RCBO for combined residual current and line protection\u003c\/h2\u003e\n\n\u003cp\u003e The ABB DS201 C13 A30 provides combined residual current and line protection for AC circuits. It trips at a fault current of 30 mA and in case of overload from 13 A. Furthermore, as a Type A device, it detects both AC and pulsating DC fault currents.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (13 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a Type A residual current device (RCD), the DS201 C13 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its C-type tripping characteristic triggers at 5 to 10 times the rated current. Therefore, it is also suitable for devices with higher inrush currents.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR255180R1134\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eRated current:\u003c\/strong\u003e 13 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS201 C13 A30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630179201402,"sku":"VER0320 \/ 2CSR255180R1134","price":59.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255180R1134_Bild2.webp?v=1772211235"},{"product_id":"abb-fi-ls-schalter-ds201-m-1-n-30ma-13a-c-typ-a-g-ds201-m-c13-g30","title":"ABB FI-LS switch DS201 M, 1+N, 30mA, 13A, C, type A\/G - DS201 M C13 G30","description":"\u003ch2\u003e ABB DS201 M C13 G30 – Residual Current Circuit Breaker with Short-Time Delay (Type G)\u003c\/h2\u003e\n\n \u003cp\u003eThe ABB DS201 M C13 G30 from the DS201 M series offers combined residual current and line protection with increased breaking capacity. It protects at a rated current of 13 A and trips at a fault current of 30 mA. This provides personal, property, and line protection in a single device.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (13 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eShort-time delayed (Type G):\u003c\/strong\u003e Prevents false tripping due to short surge currents – proven according to ÖVE standard.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n \u003cp\u003eAs a type A\/G with short-time delay, the DS201 M C13 G30 detects alternating fault currents and pulsating direct fault currents. The delay prevents unwanted tripping during short surge currents. Therefore, it is particularly widespread in Austria, conforming to the ÖVE standard. The C-type tripping characteristic triggers at 5 to 10 times the rated current. This makes it suitable for loads with higher inrush currents.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR275482R1134\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 13 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\/G\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003ch3\u003eAssembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS201 M C13 G30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630179299706,"sku":"VER0321 \/ 2CSR275482R1134","price":75.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR275482R1134_Bild2.webp?v=1772211169"},{"product_id":"abb-fi-ls-schalter-ds201-1-n-30ma-13a-c-typ-g-ds201-c13-g30","title":"ABB FI-LS switch DS201, 1+N, 30mA, 13A, C, type G - DS201 C13 G30","description":"\u003ch2\u003e ABB DS201 C13 G30 – Residual Current Circuit Breaker with Short-Time Delay (Type G)\u003c\/h2\u003e\n\n\u003cp\u003e The ABB DS201 C13 G30 provides combined residual current and line protection for AC circuits. It trips at a fault current of 30 mA and in case of overload from 13 A. Furthermore, as a Type G device, it detects both AC and pulsating DC fault currents.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (13 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eShort-time delayed (Type G):\u003c\/strong\u003e Prevents false tripping due to short surge currents – proven according to ÖVE standard.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a type G with short-time delay, the DS201 C13 G30 detects alternating fault currents and pulsating direct fault currents. The delay prevents unwanted tripping during short surge currents. Therefore, it is particularly widespread in Austria, conforming to the ÖVE standard. The C tripping characteristic triggers at 5 to 10 times the rated current. This makes it suitable for loads with higher inrush currents.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eItem number:\u003c\/strong\u003e 2CSR255482R1134\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 13 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e G\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS201 C13 G30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630179561850,"sku":"VER0322 \/ 2CSR255482R1134","price":64.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255482R1134_Bild2.webp?v=1772211118"},{"product_id":"abb-fi-ls-schalter-flexline-1-n-30ma-13a-c-typ-a-dsx301c-c13-a30","title":"ABB Residual Current Circuit Breaker FlexLine, 1+N, 30mA, 13A, C, Type A - DSX301C C13 A30","description":"\u003ch2\u003eABB DSX301C C13 A30 – Residual Current Circuit Breaker with Push-in Technology (FlexLine)\u003c\/h2\u003e\n\n\u003cp\u003e Fast installation and double protection: The ABB DSX301C C13 A30 from the FlexLine series combines residual current device (RCD) and miniature circuit breaker (MCB) functionality in a width of just 1 module. Furthermore, the push-in terminals enable tool-free wiring at the output terminals. This saves you valuable time during every installation.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (13 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePush-in technology:\u003c\/strong\u003e Tool-free wiring at the outlet for quick assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 1 TE on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a Type A residual current device (RCD), the DSX301C C13 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its C-type tripping characteristic triggers at 5 to 10 times the rated current. Therefore, it is also suitable for devices with higher inrush currents, such as air conditioners or heat pumps.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eItem number:\u003c\/strong\u003e 2CSR255165R1134\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 13 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Push-in terminals (output) \/ Screw terminals (input)\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 10 mm² (push-in), up to 25 mm² (screw)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 1 TE\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DSX301C C13 A30 snaps directly onto a 35 mm DIN rail. On the input side, you can use the screw terminal or the PSX busbar. On the output side, you connect the conductors without tools using the push-in terminals. This makes wiring particularly quick and secure. Furthermore, feed-in from both the top and bottom is possible. In addition, the integrated test button simplifies regular functional testing of the residual current device (RCD) section. The IP20 protection rating of the terminals also ensures reliable protection against accidental contact.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630179660154,"sku":"VER0323 \/ 2CSR255165R1134","price":77.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255165R1134_Bild1.webp?v=1772211014"},{"product_id":"abb-fi-ls-schalter-ds201-1-n-30ma-16a-c-typ-a-ds201-c16-a30","title":"ABB Residual Current Circuit Breaker DS201, 1+N, 30mA, 16A, C, Type A - DS201 C16 A30","description":"\u003ch2\u003e ABB DS201 C16 A30 – RCBO for combined residual current and line protection\u003c\/h2\u003e\n\n \u003cp\u003eThe ABB DS201 C16 A30 combines residual current and line protection in a single compact device. It provides protection at a rated current of 16 A and trips at a residual current of 30 mA. This gives you personal, property, and line protection in just 2 modular units.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (16 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n \u003cp\u003eAs a Type A residual current device (RCD), the DS201 C16 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its C-type tripping characteristic triggers at 5 to 10 times the rated current. Therefore, it is also suitable for devices with higher inrush currents.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR255180R1164\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n \u003cp\u003eThe DS201 C16 A30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630179922298,"sku":"VER0324 \/ 2CSR255180R1164","price":59.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255180R1254_Bild2.webp?v=1772210583"},{"product_id":"abb-fi-ls-schalter-ds201-m-1-n-30ma-16a-c-typ-a-g-ds201-m-c16-g30","title":"ABB FI-LS switch DS201 M, 1+N, 30mA, 16A, C, type A\/G - DS201 M C16 G30","description":"\u003ch2\u003e ABB DS201 M C16 G30 – Residual Current Circuit Breaker with Short-Time Delay (Type G)\u003c\/h2\u003e\n\n\u003cp\u003e The ABB DS201 M C16 G30 from the DS201 M series offers combined residual current and line protection with increased breaking capacity. It protects at a rated current of 16 A and trips at a fault current of 30 mA. This provides personal, property, and line protection in a single device.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (16 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eShort-time delayed (Type G):\u003c\/strong\u003e Prevents false tripping due to short surge currents – proven according to ÖVE standard.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a type A\/G with short-time delay, the DS201 M C16 G30 detects alternating fault currents and pulsating direct fault currents. The delay prevents unwanted tripping during short surge currents. Therefore, it is particularly widespread in Austria, conforming to the ÖVE standard. The C-type tripping characteristic triggers at 5 to 10 times the rated current. This makes it suitable for loads with higher inrush currents.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR275482R1164\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\/G\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS201 M C16 G30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n \u003cli\u003eDIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630180020602,"sku":"VER0325 \/ 2CSR275482R1164","price":75.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR275482R1164_Bild2.webp?v=1772210774"},{"product_id":"abb-fi-ls-schalter-ds201-1-n-30ma-16a-c-typ-a-g-ds201-c16-g30","title":"ABB FI-LS switch DS201, 1+N, 30mA, 16A, C, type A\/G - DS201 C16 G30","description":"\u003ch2\u003e ABB DS201 C16 G30 – Residual Current Circuit Breaker with Short-Time Delay (Type G)\u003c\/h2\u003e\n\n\u003cp\u003e The ABB DS201 C16 G30 combines residual current and line protection in a single compact device. It provides protection at a rated current of 16 A and trips at a residual current of 30 mA. This gives you personal, property, and line protection in just two modular units.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (16 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eShort-time delayed (Type G):\u003c\/strong\u003e Prevents false tripping due to short surge currents – proven according to ÖVE standard.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003ch3\u003eProtective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a type A\/G with short-time delay, the DS201 C16 G30 detects alternating fault currents and pulsating direct fault currents. The delay prevents unwanted tripping during short surge currents. Therefore, it is particularly widespread in Austria, conforming to the ÖVE standard. The C tripping characteristic triggers at 5 to 10 times the rated current. This makes it suitable for loads with higher inrush currents.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR255482R1164\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\/G\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS201 C16 G30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630180249978,"sku":"VER0326 \/ 2CSR255482R1164","price":64.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255482R1164_Bild2.webp?v=1772210709"},{"product_id":"abb-fi-ls-schalter-dsx301c-1-n-30ma-16a-c-typ-a-dsx301c-c16-a30","title":"ABB RCBO DSX301C, 1+N, 30mA, 16A, C, Type A - DSX301C C16 A30","description":"\u003ch2\u003e ABB DSX301C C16 A30 – Residual Current Circuit Breaker with Push-in Technology (FlexLine)\u003c\/h2\u003e\n\n\u003cp\u003e The ABB DSX301C C16 A30 combines residual current and circuit protection in a compact device with push-in technology. This RCBO (residual current circuit breaker with overload protection) offers a rated current of 16 A and a residual current tripping current of 30 mA. Thanks to the push-in terminals on the output terminals, wiring is particularly quick. Furthermore, the compact 1-module design saves valuable space in the distribution board.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (16 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePush-in technology:\u003c\/strong\u003e Tool-free wiring at the outlet for quick assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 1 TE on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n \u003cp\u003eAs a Type A residual current device (RCD), the DSX301C C16 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its C-type tripping characteristic triggers at 5 to 10 times the rated current, making it suitable even for devices with higher inrush currents.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR255165R1164\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Push-in terminals (output) \/ Screw terminals (input)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 10 mm² (push-in), up to 25 mm² (screw)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 1 TE\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DSX301C C16 A30 snaps directly onto the 35 mm DIN rail. On the input side, you can use the screw terminal or the PSX busbar. On the output side, you connect the conductors without tools using the push-in terminals. This makes wiring particularly quick and secure. Furthermore, feed-in from both the top and bottom is possible. In addition, the integrated test button simplifies regular functional testing of the residual current device (RCD) section. The IP20 protection rating of the terminals also ensures reliable protection against accidental contact.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630180315514,"sku":"VER0327 \/ 2CSR255165R1164","price":72.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255165R1164_Bild1.webp?v=1772210626"},{"product_id":"abb-fi-ls-schalter-ds201-1-n-30ma-25a-c-typ-a-ds201-c25-a30","title":"ABB FI-LS switch DS201, 1+N, 30mA, 25A, C, type A - DS201 C25 A30","description":"\u003ch2\u003e ABB DS201 C25 A30 – RCBO for combined residual current and line protection\u003c\/h2\u003e\n\n \u003cp\u003eThe ABB DS201 C25 A30 combines residual current and line protection in a single compact device. It provides protection at a rated current of 25 A and trips at a residual current of 30 mA. This gives you personal, property, and line protection in just two modular units.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (25 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 2 TE (35.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n \u003cp\u003eAs a Type A residual current device (RCD), the DS201 C25 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its C-type tripping characteristic triggers at 5 to 10 times the rated current. Therefore, it is also suitable for devices with higher inrush currents.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR255180R1254\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 25 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 2 TE (35.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n \u003cp\u003eThe DS201 C25 A30 easily snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. Furthermore, the test button simplifies regular functional testing of the RCD section.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630180675962,"sku":"VER0328 \/ 2CSR255180R1254","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255180R1254_Bild2.webp?v=1772210583"},{"product_id":"abb-fi-ls-schalter-ds203nc-3-n-30ma-16a-c-typ-a-ds203nc-c16-a30","title":"ABB Residual Current Circuit Breaker DS203NC, 3+N, 30mA, 16A, C, Type A - DS203NC C16 A30","description":"\u003ch2\u003e ABB DS203NC C16 A30 – Residual Current Circuit Breaker with Overcurrent Protection for Three-Phase Circuits\u003c\/h2\u003e\n\n\n\u003cp\u003e The ABB DS203NC C16 A30 offers combined residual current and line protection for three-phase circuits. It provides 3-pole protection and 4-pole switching. It reliably trips at 30 mA residual current and 16 A overcurrent. It is also suitable for three-phase loads such as cooker connections, wallboxes, or sauna heaters.\u003c\/p\u003e\n\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (16 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 4 TE (70.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a Type A residual current device (RCD), the DS203NC C16 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its C-type tripping characteristic triggers at 5 to 10 times the rated current. Therefore, it is also suitable for devices with higher inrush currents, such as air conditioners or heat pumps.\u003c\/p\u003e\n\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR256140R1164\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 3+N (3-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA (IEC\/EN 61009), 10 kA (IEC\/EN 60947-2)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 400 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 4 TE (70.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS203NC C16 A30 simply snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. This simplifies wiring when multiple devices are installed in a distribution board.\u003c\/p\u003e\n\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630180872570,"sku":"VER0329 \/ 2CSR256140R1164","price":149.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR256140R1164_Bild1.webp?v=1772210409"},{"product_id":"abb-fi-ls-schalter-ds203nc-3-n-30ma-16a-b-typ-a-ds203nc-b16-a30","title":"ABB Residual Current Circuit Breaker DS203NC, 3+N, 30mA, 16A, B, Type A - DS203NC B16 A30","description":"\u003ch2\u003eABB DS203NC B16 A30 – Residual Current Circuit Breaker with Overcurrent Protection for Three-Phase Circuits\u003c\/h2\u003e\n\n\n\u003cp\u003e The ABB DS203NC B16 A30 offers combined residual current and line protection for three-phase circuits. It provides 3-pole protection and 4-pole switching. It reliably trips at 30 mA residual current and 16 A overcurrent. It is also suitable for three-phase appliances such as cooker connections, wallboxes, or sauna heaters.\u003c\/p\u003e\n\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic B:\u003c\/strong\u003e Perfect for lighting, sockets and household appliances (16 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 4 TE (70.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n \u003cp\u003eAs a Type A circuit breaker, the DS203NC B16 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its Type B tripping characteristic triggers at 3 to 5 times the rated current. Therefore, this circuit breaker is particularly suitable for lighting, sockets, and typical household appliances.\u003c\/p\u003e\n\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR256140R1165\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 3+N (3-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e B\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA (IEC\/EN 61009), 10 kA (IEC\/EN 60947-2)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 400 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 4 TE (70.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n \u003ch3\u003eAssembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS203NC B16 A30 simply snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. This simplifies wiring when multiple devices are installed in a distribution board.\u003c\/p\u003e\n\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630181003642,"sku":"VER0330 \/ 2CSR256140R1165","price":149.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR256140R1165_Bild1.webp?v=1772210346"},{"product_id":"abb-fi-ls-schalter-ds203nc-3-n-30ma-32a-c-typ-a-ds203nc-c32-a30","title":"ABB Residual Current Circuit Breaker DS203NC, 3+N, 30mA, 32A, C, Type A - DS203NC C32 A30","description":"\u003ch2\u003e ABB DS203NC C32 A30 – Residual Current Circuit Breaker with Overcurrent Protection for Three-Phase Circuits\u003c\/h2\u003e\n\n\n\u003cp\u003e Residual current device (RCD) and line protection for 3-phase circuits in one device: The ABB DS203NC C32 A30 protects at 32 A and trips at a fault current of just 30 mA. Furthermore, it disconnects all four conductors simultaneously. This provides maximum safety for three-phase loads.\u003c\/p\u003e\n\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (32 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 4 TE (70.0 mm) on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a Type A residual current device (RCD), the DS203NC C32 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its C-type tripping characteristic triggers at 5 to 10 times the rated current. Therefore, it is also suitable for devices with higher inrush currents, such as air conditioners or heat pumps.\u003c\/p\u003e\n\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR256140R1324\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 3+N (3-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 32 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA (IEC\/EN 61009), 10 kA (IEC\/EN 60947-2)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 400 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 25 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 4 TE (70.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DS203NC C32 A30 simply snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the RCBO (residual current circuit breaker with overload protection) to the ABB PS busbar system. This simplifies wiring when multiple devices are installed in a distribution board.\u003c\/p\u003e\n\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630181298554,"sku":"VER0331 \/ 2CSR256140R1324","price":149.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR256140R1324_Bild1.webp?v=1772210279"}],"url":"https:\/\/techarena24.shop\/en\/collections\/fi-ls-schalter-abb.oembed","provider":"TECHARENA24","version":"1.0","type":"link"}