{"product_id":"abb-fi-ls-schalter-dsx301c-1-n-30ma-16a-c-typ-a-dsx301c-c16-a30","title":"ABB RCBO DSX301C, 1+N, 30mA, 16A, C, Type A - DSX301C C16 A30","description":"\u003ch2\u003e ABB DSX301C C16 A30 – Residual Current Circuit Breaker with Push-in Technology (FlexLine)\u003c\/h2\u003e\n\n\u003cp\u003e The ABB DSX301C C16 A30 combines residual current and circuit protection in a compact device with push-in technology. This RCBO (residual current circuit breaker with overload protection) offers a rated current of 16 A and a residual current tripping current of 30 mA. Thanks to the push-in terminals on the output terminals, wiring is particularly quick. Furthermore, the compact 1-module design saves valuable space in the distribution board.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (16 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePush-in technology:\u003c\/strong\u003e Tool-free wiring at the outlet for quick assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 1 TE on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n \u003cp\u003eAs a Type A residual current device (RCD), the DSX301C C16 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its C-type tripping characteristic triggers at 5 to 10 times the rated current, making it suitable even for devices with higher inrush currents.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSR255165R1164\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Push-in terminals (output) \/ Screw terminals (input)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 10 mm² (push-in), up to 25 mm² (screw)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 1 TE\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DSX301C C16 A30 snaps directly onto the 35 mm DIN rail. On the input side, you can use the screw terminal or the PSX busbar. On the output side, you connect the conductors without tools using the push-in terminals. This makes wiring particularly quick and secure. Furthermore, feed-in from both the top and bottom is possible. In addition, the integrated test button simplifies regular functional testing of the residual current device (RCD) section. The IP20 protection rating of the terminals also ensures reliable protection against accidental contact.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630180315514,"sku":"VER0327 \/ 2CSR255165R1164","price":72.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255165R1164_Bild1.webp?v=1772210626","url":"https:\/\/techarena24.shop\/en\/products\/abb-fi-ls-schalter-dsx301c-1-n-30ma-16a-c-typ-a-dsx301c-c16-a30","provider":"TECHARENA24","version":"1.0","type":"link"}