{"product_id":"abb-fi-ls-schalter-flexline-1-n-30ma-13a-c-typ-a-dsx301c-c13-a30","title":"ABB Residual Current Circuit Breaker FlexLine, 1+N, 30mA, 13A, C, Type A - DSX301C C13 A30","description":"\u003ch2\u003eABB DSX301C C13 A30 – Residual Current Circuit Breaker with Push-in Technology (FlexLine)\u003c\/h2\u003e\n\n\u003cp\u003e Fast installation and double protection: The ABB DSX301C C13 A30 from the FlexLine series combines residual current device (RCD) and miniature circuit breaker (MCB) functionality in a width of just 1 module. Furthermore, the push-in terminals enable tool-free wiring at the output terminals. This saves you valuable time during every installation.\u003c\/p\u003e\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTwo protection functions:\u003c\/strong\u003e residual current device (RCD) protection and line protection in one device – saves space and costs.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePersonal protection:\u003c\/strong\u003e 30 mA residual current tripping reliably protects against dangerous touch currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCharacteristic C:\u003c\/strong\u003e Optimal for consumers with higher inrush currents (13 A).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating and pulsating DC fault currents.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePush-in technology:\u003c\/strong\u003e Tool-free wiring at the outlet for quick assembly.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCompact:\u003c\/strong\u003e Only 1 TE on the DIN rail.\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61009 and approved worldwide.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n\u003cp\u003e As a Type A residual current device (RCD), the DSX301C C13 A30 detects both sinusoidal AC fault currents and pulsating DC fault currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers or switched-mode power supplies. Its C-type tripping characteristic triggers at 5 to 10 times the rated current. Therefore, it is also suitable for devices with higher inrush currents, such as air conditioners or heat pumps.\u003c\/p\u003e\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eItem number:\u003c\/strong\u003e 2CSR255165R1134\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N (1-pole protected, N switching)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 13 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 6 kA according to IEC\/EN 61009\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Push-in terminals (output) \/ Screw terminals (input)\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 10 mm² (push-in), up to 25 mm² (screw)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 1 TE\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The DSX301C C13 A30 snaps directly onto a 35 mm DIN rail. On the input side, you can use the screw terminal or the PSX busbar. On the output side, you connect the conductors without tools using the push-in terminals. This makes wiring particularly quick and secure. Furthermore, feed-in from both the top and bottom is possible. In addition, the integrated test button simplifies regular functional testing of the residual current device (RCD) section. The IP20 protection rating of the terminals also ensures reliable protection against accidental contact.\u003c\/p\u003e\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61009-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-20, 0664-21\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56630179660154,"sku":"VER0323 \/ 2CSR255165R1134","price":77.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSR255165R1134_Bild1.webp?v=1772211014","url":"https:\/\/techarena24.shop\/en\/products\/abb-fi-ls-schalter-flexline-1-n-30ma-13a-c-typ-a-dsx301c-c13-a30","provider":"TECHARENA24","version":"1.0","type":"link"}