{"product_id":"abb-fi-schutzschalter-f200-4-polig-300ma-63a-typ-a-f204-a-s-63-0-3","title":"ABB residual current circuit breaker F200, 4-pole, 300mA, 63A, type A - F204 A S-63\/0.3","description":"\u003ch2\u003e ABB F204 A S-63\/0.3 – 4-pole selective residual current circuit breaker (Type S)\u003c\/h2\u003e\n\n\n\u003cp\u003e The ABB F204 A S-63\/0.3 is a selective 4-pole residual current circuit breaker (RCCB) for use as upstream protection. It operates with a time delay and trips at a fault current of 300 mA. This ensures that in the event of a fault, only the downstream circuit remains de-energized.\u003c\/p\u003e\n\n\n\u003ch3\u003e Your benefits at a glance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFire protection:\u003c\/strong\u003e A 300 mA trigger current prevents electrically ignited fires.\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003ePulse current sensitive (Type A):\u003c\/strong\u003e Detects alternating fault currents and pulsating direct fault currents – for modern electronics.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eScrew terminals:\u003c\/strong\u003e Proven and safe connection technology for conductor cross-sections up to 35 mm².\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eSpace-saving:\u003c\/strong\u003e Compact 4-TE design (70.0 mm) for DIN rail mounting.\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eSelective (Type S):\u003c\/strong\u003e Time-delayed tripping for selective protection setup with downstream residual current circuit breakers (RCCBs).\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eABB quality:\u003c\/strong\u003e Tested according to IEC\/EN 61008 and approved for worldwide use.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Protective function and use\u003c\/h3\u003e\n\n \u003cp\u003eType A residual current device (RCD) detects both sinusoidal alternating currents and pulsating direct currents. This makes it suitable for circuits with modern electronic devices such as LED dimmers, switched-mode power supplies, or induction cooktops. The rated residual current of 300 mA primarily serves fire protection. This ensures that dangerous fault currents are detected before they can overheat wiring. Furthermore, this selective variant (Type S) operates with a time delay. Therefore, in the event of a fault, only the affected circuit is de-energized, while the rest of the system continues to function. Experts also recommend regularly testing the RCD using the test button.\u003c\/p\u003e\n\n\n\u003ch3\u003e Technical data\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eArticle number:\u003c\/strong\u003e 2CSF204201R3630\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 4-pole\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 63 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 300 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eType:\u003c\/strong\u003e A (selective)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230\/400 V AC\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTerminal type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e up to 35 mm²\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eDivision units:\u003c\/strong\u003e 4 TE (70.0 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003e Assembly and wiring\u003c\/h3\u003e\n\n\u003cp\u003e The F204 A S-63\/0.3 simply snaps onto a 35 mm DIN rail. You then connect the conductors using the screw terminals. Power can be fed in from both the top and bottom. Additionally, you can connect the residual current device (RCD) to the ABB PS busbar system. This eliminates the need for complex individual wiring. Furthermore, the test button simplifies regular functional testing.\u003c\/p\u003e\n\n\n\u003ch3\u003e Standards and approvals\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e IEC\/EN 61008-1\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0664-10, 0664-11\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-410\u003c\/li\u003e\n\n\u003cli\u003e DIN VDE 0100-530\u003c\/li\u003e\n\n\u003cli\u003e CE marked\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56629075050874,"sku":"VER0297 \/ 2CSF204201R3630","price":164.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/2CSF204201R3630_Bild1.webp?v=1772206508","url":"https:\/\/techarena24.shop\/en\/products\/abb-fi-schutzschalter-f200-4-polig-300ma-63a-typ-a-f204-a-s-63-0-3","provider":"TECHARENA24","version":"1.0","type":"link"}