{"product_id":"eaton-fi-ls-schalter-kennlinie-b-1-n-10a-30ma-pknm-10-1n-b-003-a-m","title":"Eaton RCBO, characteristic B, 1+N, 10A, 30mA (PKNM-10\/1N\/B\/003-AM) - 236072","description":"\u003ch2\u003eEaton PKNM-10\/1N\/B\/003-AM Residual Current Circuit Breaker with Overcurrent Protection – 10 A, Characteristic Curve B, 30 mA\u003c\/h2\u003e\n\n\u003cp\u003e The Eaton PKNM-10\/1N\/B\/003-AM residual current circuit breaker (RCCB) from the xPole series combines residual current protection and circuit protection in a single compact device. This saves valuable space in the distribution box and significantly reduces wiring effort.\u003c\/p\u003e\n\n\u003cp\u003e This residual current circuit breaker (RCCB) operates with a rated current of 10 A and a tripping characteristic of B (for resistive and mixed loads). The 30 mA residual current reliably protects people from dangerous electric shocks. The RCCB protection is type A (pulse current sensitive). This means the device detects both sinusoidal AC residual currents and pulsating DC residual currents. Therefore, it is the right choice for circuits with electronic devices.\u003c\/p\u003e\n\n \u003cp\u003eTherefore, this residual current circuit breaker (RCCB) is particularly suitable for homes, offices, and light commercial buildings. Furthermore, its B-curve characteristic is ideal for lighting, sockets, and heating systems. You benefit from proven Eaton quality and a rated breaking capacity of 10 kA.\u003c\/p\u003e\n\n\u003ch2\u003e Technical data – PKNM-10\/1N\/B\/003-A-MW\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eModel code (Eaton):\u003c\/strong\u003e PKNM-10\/1N\/B\/003-A-MW\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCatalogue number (SKU):\u003c\/strong\u003e 236072\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eEAN:\u003c\/strong\u003e 4015082360726\u003cbr\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 1+N-pole\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated current:\u003c\/strong\u003e 10 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eTrigger characteristic:\u003c\/strong\u003e B\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated residual current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eFI type:\u003c\/strong\u003e Type A (pulse current sensitive)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated breaking capacity:\u003c\/strong\u003e 10 kA (according to IEC\/EN 61009)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 230 V AC, 50 Hz\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated insulation voltage:\u003c\/strong\u003e 440 V\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eRated impulse withstand voltage:\u003c\/strong\u003e 4 kV\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eProtection rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eWidth:\u003c\/strong\u003e 2 TE (division units)\u003c\/li\u003e\n\n\u003cli\u003e \n\u003cstrong\u003eConnection cross-section:\u003c\/strong\u003e 1–25 mm² (single and multi-strand)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail (35 mm)\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eWeight:\u003c\/strong\u003e 0.192 kg\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003ePower loss:\u003c\/strong\u003e 2.5 W\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eEnergy limiting class:\u003c\/strong\u003e 3\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -25 °C to +40 °C\u003c\/li\u003e\n\n\u003cli\u003e\n\n \u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, RoHS compliant\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e The device is tested according to IEC\/EN 61009 and bears the CE marking. It also complies with the RoHS directive. Therefore, it meets all requirements for use in Austria and the EU.\u003c\/p\u003e\n\n\u003cp\u003e Installation is simple thanks to the snap-in mounting on the DIN rail. No special tools are required. Additionally, conductor cross-sections from 1–25 mm² can be connected – covering most installations.\u003c\/p\u003e\n\n \u003cp\u003eIn summary, the Eaton PKNM-10\/1N\/B\/003-AM residual current circuit breaker with overload protection offers reliable personal and line protection in a single device. This saves you space, time, and wiring effort during installation. Consequently, it is the efficient solution for your distribution board.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":55958453879162,"sku":"VER0891 \/ 236072","price":99.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0919\/8793\/5610\/files\/236072.webp?v=1758978895","url":"https:\/\/techarena24.shop\/en\/products\/eaton-fi-ls-schalter-kennlinie-b-1-n-10a-30ma-pknm-10-1n-b-003-a-m","provider":"TECHARENA24","version":"1.0","type":"link"}